| Description | Applications | Available Models | Installation | | Typical Application | Specification Form | |
|
||
| Description RAF 30-33 valves are activated by line pressure. The valves open or close by electric command through a selection of solenoid valves. The solenoid opens or closes the RAF as it energized by an electric pulse. The electric pulse originates with a controller, timer, sensor or remote control device. |
Available Models RAF 30 - Two-way Normally Closed electric control valve RAF 32- Two-way Normally Open electric control valve RAF 31- Three-way Normally Closed electric control valve RAF 33 - Three-way Normally Open electric control valve |
|
| Applications On-Off electric valves are used for remote control of hydraulic valves. Normally Open or Normally Closed configurations are available. |
||
|
|
|
| Installation Normally Closed Mode By default, the line pressure is connected to the RAF valve control chamber above its diaphragm via ports 1-2. Thus, the diaphragm is pressed downwards against the valve seat. As the solenoid is energized by an electric pulse, its core flips to the left. Port 1 closes & the vent opens. The RAF control chamber drains out. The RAF s diaphragm is forced upward by line pressure. The RAF fully opens. Normally Open Mode By default, the RAF control chamber is connected to the vent of the solenoid. Thus its diaphragm is pressed upward by line pressure. The RAF is fully open. As the NC solenoid is energized by an electric pulse its core flips right. The vent closes & port 1 opens. The line pressure is then connected to the RAF control chamber & pushes the diaphragm all the way downward. The RAF closes. |
||
| Two-way
configuration: The RAFs control chamber drains downstream, enabling faster & gradual opening without water spill. Three-way configuration: The RAFs control chamber drains out, enabling the valve to open fully. |
Typical Application
|
|
Electric Control Valve |
Configuration |
Model |
Please Specify:
|
| NC-2 way | RAF 30 | ||
| NO-2 way | RAF 32 | ||
| NC-3 way | RAF 31 | ||
| NO-3 way | RAF 33 |
Standard RAF 20 |
Special Features |
|
| Complete basic RAF valve as specified above | Enamel/epoxy coating | |
| Assembled 24V-AC Solenoid | Other solenoids upon request | |
| Self-cleaning screen filter | External heavy duty screen filter | |
| 3/8" Reinforced Plastic tubing | Copper or stainless steel tubes |
|
3-way/2-way solenoid valve |
AC-50/60 Hz | 24V, 110V, 220V |
| DC | 12V, 24V |
|
| Latch | Available upon request |
|
![]() |
|||